- Home
- ยป
- Our Products
- »
- Biochemistry Analyzer
Biochemistry Analyzer
Semi Auto Biochemistry Analyzer
Automation | Semi Automatic |
Brand | Athenese |
Assays | Clinical Chemistry |
Reaction Cuvette | Flow Cell |
Storage | Box |
Usage/Application | Industrial |
Wavelength | 10 Nn |
Country of Origin | Made in India |
BS 240 Pro Chemistry Analyzer
Minimum Order Quantity: 1 No
Product Brochure
Instrument Name | Biochemistry Analyzer |
Model Name/Number | BS-240 Pro |
Brand | Mindray |
Display | Digital |
Water Consumption/Hr | < 6.5 L/H |
Frequency | 50/60 Hz |
Voltage | 200~240 V |
Light Source Lamp | Halogen Tungsten Lamp |
Interface | RS - 232 |
Throughput | Constant 240 photometric tests per hour, up to 400 T/H with ISE |
Weight | 115 kg |
Reaction tray | 80 reusable cuvettes |
Reaction volume | 100~360 iL |
Reaction temperature | 37 Degree C +- 0.1 Degree C |
Stray Light | 4.9 Abs |
Operation System | Windows 10 |
Dimension: | 860 mm (length) x 660 mm (depth) x 550 mm (height) |
Absorption Range | 0~3.5 Abs, Resolution 0.0001 Abs |
Product Detail :
System Function
Automatic, Discrete, Random Access, Bench-topSTAT sample priority
Throughput:
Constant 240 photometric tests perhour, up to 400 T/H with ISE
Measuring Principles:
Absorbance photometry,turbidimetry, ion selective electrodetechnology
Methodology:
End-point, Fixed-time, Kinetic,optional ISE,Single/Double reagent chemistries,Mono-chromatic / bi-chromatic
Original system pack reagent ready to useClose system and open system is optional
Reagent/Sample Handling
Reagent/Sample Tray:
50 to 100 positions for reagents and 50to 100 positions for samples in 24-hourrefrigerated compartment (2~12 Degree C)
Reagent volume:
R1: 100~200L, step by 0.5LR2: 10~200L, step by 0.5L
Sample Volume :
2~35L, step by 0.1L
Reagent/Sample Probe:
Liquid level detection, horizontal andvertical collision protection, inventorychecking, reagent pre-warming,optional clog detection
Probe Cleaning:
Automatic washing for interior andexteriorCarry over < 0.05%
Automatic sample dilution:
Pre-dilution and post-dilution
Mixing Unit:
Independent Mixing Bar
Built-in Bar Code Reader (Optional)
Used for sample and reagent programmingBe applicable to various bar code systems of Codabar, ITF (Interleaved Two of Five), code128, code39, UPC/EAN, Code93Capable to communicate with LIS in bi-directional mode
Reaction System
Cuvette Washing:
Washing station with pre-warmeddetergent and de-ionized water
ISE Module (optional)
Measuring K+, Na+, Cl-
Wavelength:
12 wavelengths, 340nm, 380nm, 412nm,450nm, 505nm, 546nm, 570nm, 605nm,660nm, 700nm, 740nm, 800nm
Control and Calibration
Calibration modes:
factor, Linear (two points andmulti-points), Logit-Log 4P, Logit-Log 5P,Spline, Exponential, Polynomial, Parabola,Logit-Log3P, Broken lineOne key calibrator import function
Control Rules:
Westgard multi-rule, Levey-Jennings,Cumulative sum check, Twin plot
Large and flexible capacity
Up to 100 sample positions
Up to 100 reagent positions
(50 fixed + 50 interchangeable)
Gratings photometer
100L minimum reaction volume
Complete Traceability Process
Complete calibration hierarchy and traceability chain are based on ISO standard (EN/ISO17511) from reference systemto routine measurement system.
External quality assurance for reference measurement:
Mindray participates in RELA (External quality control for reference laboratory).
EQA for Mindray Reference laboratory——RELA
Mindray reference laboratory has passed RELA for 6 consecutive years.
HumaStar 200 Biochemistry Analyser
Product Brochure
Model Name/Number | HumaStar 200 |
Brand | Human |
Automation | Fully Automatic |
Display | Digital |
Dimensions | 69 x 76 x 52 cm (WxDxH) |
Frequency | 50/60 Hz |
Voltage | 220-240 or 110-120 Vac |
Temperature | 16-30 Degree C |
Throughput | Up to 200 t/h throughput |
Weight | 51 kg |
Reaction volume | 210-350 il |
Wash station | 6 dispensing needles Water consumption < 2 l/h (8 ml/test) |
Languages | English, French, Spanish Software (other languages can be added) |
Humidity | < 80 % non-condensing |
Data | External computer required (Pentium IV, 2 GHz |
Mode | Open, random-access, STAT |
Unique Random-Access Analyzers for Small to Medium Size Laboratories
- Unique design
- Unique software architecture
- Unique features
Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters)
Samples
Removable sample tray
60 positions: primary tubes 12–12.5x100 mm and 10 mm cups
Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml
Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates
Reagents
Removable reagent tray
30 reagent / diluent positions
50 and 20 ml bottles, adapter for tubes and cups
Reagent volumes: 5–350 µl
Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric
Reaction
Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air
Pipetting
Needle shock detector Capacitive liquid level detector
Wash station
8-step cuvette wash station Systemic and special washing solution
HumaStar 200:
6 dispensing needles Water consumption < 2 l/h (8 ml/test)
Optical system
9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day
Management
20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet
Printouts
By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing
C73 BenaSphera Chemistry Analyzer
Minimum Order Quantity: 1 Unit
Product Brochure
Brand | BenaSphera |
Model Name/Number | C73 |
Power Supply | 110 to 240 V |
Resolution | 0.0001ABs |
Interface | R 232 |
System Fuction | Automatic |
Principles | Absorbance Photomentry |
Mothdology | End Point |
Programming | Open System |
Sample Tray | 40 Sample Position |
Sample Prove | Liquid label detection and tracking |
Liquid Source | Halogen |
Photometer | Grating System |
Mixing Ststem | Standalone |
Cuvatte Washing | 8 Step washing System |
Temperature | 15 to 30 Degree |
Intelligent collision protection
- Vertical & horizontal collision
- Audible alarm
- Ensure operatorsafety
- Effective liquid level detection
- Liquid level tracking
- Prevenxshorrsampling
Semi-permanent cuvettes
- Lowerconsumablecost
- Easy replacement
- Durable material, long lasting
Reagent and sample cooling compartment
- 2~12°C continuous cooling
- Enhance reagentand sample stability
- Reagents, QC and CAL
- Metrological traceability
- 12 Waveiengihs; up to 800nm
- Reversed optics
- Actornodate most chemistry assays
- Enable lengthy opevator walk away time
- High quality cuvette washingr
- Ensure optimal cleanlness with ple>heaieddexevgem and water
- Effectively minimizes potential carryover- Innovative design
- Minimal maintenance; simple installation
- Lower Reagent Consumption
- Long term saving on reagent cost
- Na‘, K‘, CI’ electrodes
- Durable assemble
- Highly ef???cient electrolyies analysis
Csense 100 Auto Chemistry Analyzer
Minimum Order Quantity: 1 No
Product Brochure
Brand | Medsource Ozone |
Model Name/Number | Csense 100 |
Water Consumption/Hr | 3 to 5 |
Throughput | 100-120 t/h (single /double Reagent ) |
Weight | 40 Kg |
Analysis Method | End Point |
Voltage | AC 110/20 V |
Frequency | 50-60 Hz |
Resolution | 0.00001 Abs |
Dimension | 500Mm*440Mm*470Mm |
Power | 300 W |
Interface | Standard R232 |
System | Discrete Random access |
Light Source | 100W/6V |
Sample Position | 20+2 |
Humidity | 30 to 80% |
Temprature | 15 to 30 Degree |
Operating System | Win XP/ Win 8/ Win 7 |
Regent Bottle | 20 Ml |
Control Rule | Westgard Multi rule |
Reaction Temperature | 37 Degree C |
System Function:
System : Discrete ramdom access
Analysis method : End point,Two Point,Kinetic
Sample & Regent System
Sample Positions : 20+2 Positions ,up to 71
Sample & Regent probe : 1 independent polished treated probe with mixing function
Sample Valume : 2-100 il,0.1 il stepping
Sample & Regent probe technology : X+Y+Z dispensing system liquid level detection
Sample & Regent probe cleaning : Automatic washing both interior and exterior
Regent position : 50 positions with on board cooling
Regent Volume : 15-300 il,1 il stepping
Reaction System
Cuvette Specification : Individually positioned cuvette optical diameter of 5.8 mm
Reaction Volume : 180 il-500 il
Reaction Temperature : 37 Degree C
Waste Water Treatment : Waste liquid level alarming De ionized water level alarming Reaction
Cuvette cleaning : on board 6 stage cuvette washing
Optical System
Wavelength : 8 wavelength : 34nm,405nm,450nm,510nm,546nm,578nm,630nm,700nm
Calibration And QC
Calibration Rules :10 type (Factor,1-point,2-point,Multipoint,Spline,Logit-log 4P/5P,Exp 5P,Poly 5P,Parabola)
Control Rule : Westgard multi-rule ,L-J plot
Liquid Handling
- Unique discrete, X+Y+Z dispensing system
- Reagent/Sample probe with stirrer mixing facility
- Liquid level detectionCollision protection of probe
- Automatic probe washing by internal, externaland stirrer wash
- Backed by maintenance-free diluter
- Automatic 6—stage on—board washing station
- Maintenance—free vacuum pumps
- Automatic cuvette auto—zero afterwashing of each cuvette
- Alarm for waste liquid level & de—ionizedwater level
- Flexible drawer—style reagent and samplerack
- Interchangeable reagent and sampleposition
- Max 50 reagent positions and max. 71sample positions
- Continuous sample loading
- Cooled reagent unit with peltier elements
- Suitable for direct placement of OzoSenseSystem Reagent bottles
- 48 individually positioned reactioncuvettes
- High quality reusable cuvettes
- Thermostat technology to maintaintemperature at 37°C
- Small foot-print with powerful aesthetics (0.1 m3)
- The most compact automated chemistry andturbidimetry analyzer
- Constant throughput of 100 tests/hr. with typicalworkload with max. throughput upto 120 tests/hr.
- On-line inventory for reagents, waste and de-ionized water
- Easy profiling of any assays
- On-line graph monitoring for any reactions
- Pre-programmable auto-serial dilution of calibrators
- Min. sample volume of 2 ul
- Min. reaction volume of 180 pl
- On-board laundry with no additional consumables
- Pre-programmed with OzoSense System Packs
- Reliable results and stable performanceEmpowered by Ozo Sense
HumaStar 300SR Clinical Chemistry Analyzer
Minimum Order Quantity: 1 No
Product Brochure
Brand | Human |
Model Name/Number | HumaStar 300 SR |
Power Supply | 110 to 240V |
Weight | 75 Kg |
Operation | Clinical chemistry and turbidimetry |
Software | External computer required |
Environment | Less than 300 VA |
Temprature | 16 to 30 Degree |
Humididty | Upto 80% |
Samples | 60 positions |
Reagents & solutions | 2 removable reagent trays |
Pipetting | 2 pipetting needles |
Reaction | 8-step cuvette wash station |
Sample Tray | 16 mm + cups |
Reagent Tray | 20 positions |
Sample Tubes 5 ml | 1000 pcs |
- Rock-solid, Reliable and Worry-free
- Upgrade to proven quality and cutting-edge technology
- Provide reliable results
- Ease your daily routine
- Proven Hardware and Software Quality of HumaStar 100 / 200
More than 40 Years of Experience in Clinical Chemistry - More than 40 Years of Experience in Clinical Chemistry
- Perfectly matching analyzer, reagents, methods,calibrators, controls
- Two reagent kit sizes
- Ready-to-use and validated
- Automatic check of instrument and results
- Minimal carry-over – dual solution wash station
- Low water consumption (< 3 l/h)
- Segregation and reduction of biohazard waste
- Clinical chemistry and turbidimetry
- Random access, STAT
- System reagent methods preinstalledand validated
- Open channels with barcoded bottles
- Up to 290 tests / hour
- Removable sample tray
- 60 positions
- 12.5 mm primary tubes and 1 ml cups
- Optional 16 mm tubes and 3.5 ml cups
- Automatic pre- and post-dilution
- Internal barcode reader
- 2 removable reagent trays
- 40 positions
- 70 and 25 ml bottles
- Electronically controlled cooling
- 2 pipetting needles
- Needle shock detector
- Capacitive liquid level detector
- Internal-, external- and methodspecific wash procedures
- 8-step cuvette wash station> Less than 3 l / h water consumption
- Two different wash solutions> Method specific wash procedures
- Separate containers for normal andhigh contaminated waste
- External computer required
- LIS: Bi-directional, ASTM, ethernet
- English, French, Spanish
- Designed for touchscreen
- Automatic check of reagents, expirydates, calibration, hardware,maintenance, reaction and results
100 – 240 V, 50 / 60 Hz
Less than 300 VA
93 x 74 x 60 cm (W x D x H)
Approx. 75 kg
16 – 30 °C, < 80 % humidity
Reagent kits
Please see our flyer „Clinical ChemistryLine“ and catalog for available reagentkits and wash solutions.Reagent OverviewAll information preliminary and subject to change
Full Flexibility
- Huge variety of primary and secondary sample tubes
HumaStar 100 Biochemistry Analyser
Product Brochure
Model Name/Number | HumaStar 100 |
Brand | Human |
Automation | Fully Automatic |
Display | Digital |
Dimensions | 69 x 76 x 52 cm (WxDxH) |
Frequency | 50/60 Hz |
Voltage | 220-240 or 110-120 Vac |
Temperature | 16-30 Degree C |
Throughput | 100 t/h constant throughput |
Weight | 51 kg |
Reaction volume | 210-350 il |
Wash station | 6 dispensing needles Water consumption < 2 l/h (8 ml/test) |
Languages | English, French, Spanish Software (other languages can be added) |
Humidity | < 80 % non-condensing |
Mode | Open, random-access, STAT |
Data | External computer required (Pentium IV, 2 GHz |
Unique Random-Access Analyzers for Small to Medium Size Laboratories
- Unique design
- Unique software architecture
- Unique features
Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters)
Samples
Removable sample tray
60 positions: primary tubes 12–12.5x100 mm and 10 mm cups
Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml
Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates
Reagents
Removable reagent tray
30 reagent / diluent positions
50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl
Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric
Reaction
Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air
Pipetting
Needle shock detector Capacitive liquid level detector
Wash station 8-step cuvette wash station Systemic and special washing solution
HumaStar 100: 4 dispensing needles Water consumption < 1 l/h (8 ml/test)
Optical system
9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day
Management
20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet
Printouts
By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing
BS 380 Bio Chemistry Analyzer
Minimum Order Quantity: 1 No
Product Brochure
Brand | Mindray |
Model Name/Number | BS 380 |
Assays | Clinical Chemistry |
Reaction Cuvette | Optical length of 5mm |
Water Consumption/Hr | 10 L/hour |
Wavelength | 340nm 380nm 412nm 450nm 505nm 546nm 570nm 605nm 660nm 700nm 740nm ,800nm |
Weight | 200 Kg |
Voltage | AC 100~240V,000VA |
Frequency | 50 / 60Hz |
Resolution | 0.001 Abs |
Dimension | 990mm x 693mm x 1135mm (WxDxH) |
Interface | RS-232 |
Temperature | 15~30 Degree C |
Light Source | Halogen-tungsten lamp |
Photometer | Reversed optics, grating photometry |
Manufactured By | Avantor |
Operation System | Windows XP Professional/Home SP2 or above Windows Vista Home/Business, Windows 7 |
Humidity | 35~85% RH |
Operating System | Windows XP, Window 7, Window 8 |
Mixing System | Integrated mixers system |
Absorbance Range | 0~3 Abs |
Temperature fluctuation | +- 0.1 Degree C |
Reaction volume | 150~360 il |
Reaction Rotor | Rotating tray, 72 cuvettes with automatic washing |
- Discrete, random access, fully automated
- Constant 300 tests per hour, up to 450 tests perhour with ISE
- Onboard capacity of 75 sample positions, up to58 chemistries plus 3 ions
- Refrigerated reagent compartment
- Automatic probe cleaning, liquid level detection,vertical and horizontal collision protection
- 8-step auto washing system12 wavelengths: 340~800nm
- Automatic dilution for abnormal sample
- Internal bar code reader (optional)Bi-directional LIS interface
- 75 sample positions
- Can be programmed into 5 virtual sample disks
- Primary tubes and various sample cups can be used
- Automatic dilution of high concentration samplePre-dilution for samples
- Internal sample bar code reader (optional)
- Liquid level detection
- Collision protection
- Inventory monitoringProbe depth adjusted automatically
- 150 μL minimum total reaction volume
- Test sequence optimization
- Contains 72 reaction cuvettes
- Maintenance free heating system
- High-tech washing station to ensure
- accurate results and valid diagnostics
- Concentrated detergents to reduce carry-over
- 8-step auto washing station
- Integrated mixers system
- Optimized homogenization
- High precision mixer station to ensure excellentreaction conditions
- Standardized mixing proceduresInterior and exterior probe washing
- Separate mixer for individual reaction steps
- 58 reagent positions for R1, R224 hour non-stop cooling with Peltier element
- Ready-to-use liquid stable reagents
- High-tech washing station to ensure
- Internal reagent bar code reader (optional)
- Running status of reagent tray, sample tray and reaction tray
- Real-time monitoring of reagent residual volume
- Real-time diagnosis of system working status
- Template Modifying Software
- Flexible to dene various report templates for laboratory, and easy to import new template from Mindray or other users.
- Monitoring of various SamplesIt
- is method to perform continuous glucose monitoring in subjects with impaired glucose tolerance or other multiple samples monitoring.
- Fast Emergency Detection
- One-key STAT function makes it easy to perform an emergency test for operator.
- Real-time monitoring of reactions
- Simultaneously display reaction curves under primary and secondary wavelengths
- Detailed profile of alert messages
Fully automated, Discrete, Random access for routine, STAT, Urine and homogeneous immuno assays;STAT sample priority
Methodology
End-point, Fixed-time, Kinetic, optional ISESingle / Dual reagent chemistries,monochromatic / bichromaticLinear / non-linear calibration
Internal Bar Code Reader (optional)
Used for sample and reagent programming;applicable to various bar code systemsincluding Codabar ITF Code128Code 39 UPC / EAN Code 93.Bi-directional LIS interface
Sample probe:
Liquid level detection, vertical and horizontalcollision protection
Probe cleaning:
Interior and exterior automatic washingCarry-over< 0.1%
BeneSphera C61 Semi Automatic Biochemistry Analyser
Minimum Order Quantity: 1 No
Product Brochure
Automation | Semi Automatic |
Brand | BeneSphera |
Model Name/Number | C61 |
Assays | Clinical Chemistry |
Flow Cell | Metal - quartz flow cell, capacity 32 l |
Voltage | AC 100 V - 240 V + -10% |
Frequency | 50-60 Hz |
Resolution | 0.001Abs (Display), 0.0001 Abs (Calculation) |
Dimension | 360 x 318 x 139 LxWxH (mm) |
Interface | RS 232 serial cable |
Manufactured By | Avantor |
Absorbance | -0.5-3.0A |
Light Source | Halogen Tungsten Lamp |
Wavelengths | 340, 405, 500, 546, 578, 620 (300 nm - 800 nm) |
Wavelength Accuracy | + - 1nm |
Data Storage | Memory for 60 programs and 2000 test results |
Band Width | < 8nm |
Temperature Control | Peltier 25 Degree C , 30 Degree C, 37 Degree C + -1 Degree C and ambient temperature |
Aspiration | System Double aspiration with Air Gap after each sample |
Cross Contamination Rate | < 1% |
Display | LCD Display |
Output | Internal Printer |
Net Weight | 7 kg |
Features and Benefits
- High precision and excellent reproducibility for reliable reporting
- Excellent QC function with the option of 2 levels of programmable controls per test
- Double aspiration air gap after each sample prevents cross-contamination
- LCD display allows for easy keypad operation
- Memory for 60 programs and 2000 test results - suitable for running profiles
- Avantor Performance Materials manufactures and markets high-perfirmance chemistries and materials around the world under several respected brand names,including the J.T. Baker, Macron fine chemicals Rankem ,BeneSphera and POCH brands
- Avantor products are used in a wide range of industries .Our boimedical and life science solutions are used in pharmaceutical production,laboratory research fir acadmic ,industry and quality control ,and in medical lab testing .Our electrinics material products are used in the manufacturing of semiconductors.
HumaStar 600 Clinical Chemistry Analyzer
Minimum Order Quantity: 1 No
Product Brochure
Brand | Human |
Model Name/Number | HumaStar 600 |
Assays | Clinical Chemistry |
Throughput | Upto 800 Tests/h |
Weight | 180 Kg |
Analysis Method | End point with sample |
Power | 110/220 V 50/60 Hz, 1.400 VA |
Calibration | Single and Multi point |
Water Consumption | Less then 4 |
Results Per Hours | Up to 600 |
Regents/Method | Up to 3 |
Re-usable Reaction covettes | 160 |
Regent Storage | 24 Hours |
Dimenriom | 100{w) x 74 (D) r 113 (H).m |
Environment | Temperaturemax. So'c |
Reagents | 48 Single Reagents |
Backup | Automatic |
Control | Westgard |
Printouts | Customer definable reports, optimized printouts of results |
Data | Window Based software |
Wash Statation | 6 stage |
Reaction | 2x80 re-usable plastic cuvettes (6mm) |
Mode | Closed system with 5 open channels |
Random-Access Clinical Chemistry System5o easy to handle
- Highthroughput
- Reliable pedormance
- workflow-optimized handling
Ef???cient Operation
- Less than 4 water consumption
- Ready to use HUMAN System Reagents
- Up to 600 results/hour w/o ISE
- Up to three reagents/method
- 160 re-usable reaction cuvettes
- Two independent reaction carousels
- 24 hour on board reagent storage
- Random-access for reagents and samples
- Minimal reagent consumption
- Automated pre/post-dilution
- Clot detection
- Validated HUMAN assay applications
- internal and external probe washing
- Two independent pipettors
- Easy to use software
- 48 cooled reagents on board
- Barcode recognition of reagents, samples and racks
- Convenient loading of reagents, samples andconsumables
- 95 samples (5 racks x19)
- Stat rack for immediate measurement
- Liquid level sensor
- More than 40 HUMAN high quality system reagents:Ready To use Barcode Long on board stability (up to 60 days)Long calibration stability (upto 60 days),
- validated and optimized applications minimal reagent consumption High Sensitivlty and wide linearity range
- Up to 5 open channel for user defined methods
- Serum / plasma or urine samples
- Upto 100 samples / hr
- 6 to 12 months on board stability of electodes
- ISE unit retrofittable
- High precision - small filter bandwidth
- High resolution
- Large measuring Range
- Suitable for most tests between 340 to 800 nm (filters on board )
- lndividual optimization of each assay run
- Faster Run
- Highest quality of results
- Ensuring reliability of results
- Optional manually iniliated cuvette washing
- Color Coading
- lmmediate access to problem solution
- Minimizing operator error
- Flexlble operations through user defined panels
- Simplified distribution of workflow
- Enhanced reliabilaty of results due to reparation of critical assay combinations
- Reagent consumption monitor alerts before run
- LIS Capable
- Multiple printing option
- lntelligent invenlory management
- Multi reagent placement for any given method
- Lot specific calibration
- Multiple password protected access levels
- Automaiic maintenance information
- Built In QC module
- Automatically back up